Standard Hybrid Control Station Combiners

These multi-channel combiners provide frequency-agile operation across their entire frequency range. CSCs may be used to reduce the number of antennas required on a communications site whilst also ensuring that predictable radio-to-radio isolation is maintained at all times - irrespective of individual Tx or Rx operating modes.

Features:
  • Broadband operation
  • Models available to suit half-duplex or full-duplex radios
  • Available in capacities from 4 to > 128 ports
  • Compact size. Easily installed and relocated
  • Convenient field expandability

Product Filter

Frequency Band


Frequency in MHz


Part Number Product Description Conn. TypeFreq BandFreq MHzInsertion Loss (dB)Min. Tx to Tx Freq. SeparationReturn Loss dBRF Power W
App Note - CSC Standard Control Station Combiner Application Note
CS8996-3205-SN Hybrid Control Station Combiner, 890-960 MHz, 32 Channel N (F) 900 890 – 960 18.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS7486-1605-SN Standard Control Station Combiner, 746-870 MHz, 16 Channel N (F) 700/800 746 – 870 15dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS7486-2405-SN Standard Control Station Combiner, 746-870 MHz, 24 Channel N (F) 700/800 746 – 870 18.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous), –
CS7486-3205-SN Standard Control Station Combiner, 746-870 MHz, 32 Channel N (F) 700/800 746 – 870 18.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS8996-0405-SN Hybrid Control Station Combiner, 890-960 MHz, 4 Channel N (F) 900 890 – 960 8.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS8996-0805-SN Hybrid Control Station Combiner, 890-960 MHz, 8 Channel N (F) 900 890 – 960 11.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS8996-1205-SN Hybrid Control Station Combiner, 890-960 MHz, 12 Channel N (F) 900 890 – 960 15dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS8996-1605-SN Hybrid Control Station Combiner, 890-960 MHz, 16 Channel N (F) 900 890 – 960 15dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS8996-2405-SN Hybrid Control Station Combiner, 890-960 MHz, 24 Channel N (F) 900 890 – 960 18.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS7486-1205-SN Standard Control Station Combiner, 746-870 MHz, 12 Channel N (F) 700/800 746 – 870 15dB (typ.) 0MHz, – > 14dB Per Channel: 50 (continuous), –
CS4552-0805-SN Standard Control Station Combiner, 450-520 MHz, 8 Channel N (F) UHF 450 – 520 11.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS4552-1205-SN Standard Control Station Combiner, 450-520 MHz, 12 Channel N (F) UHF 450 – 520 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS4552-1605-SN Standard Control Station Combiner, 450-520 MHz, 16 Channel N (F) UHF 450 – 520 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS4552-3205-SN Standard Control Station Combiner, 450-520 MHz, 32 Channel N (F) UHF 450 – 520 17dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS7486-0405-SN Standard Control Station Combiner, 746-870 MHz, 4 Channel N (F) 700/800 746 – 870 8.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS7486-0805-SN Standard Control Station Combiner, 746-870 MHz, 8 Channel N (F) 700/800 746 – 870 11.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS4552-0405-SN Standard Control Station Combiner, 450-520 MHz, 4 Channel N (F) UHF 450 – 520 8dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1517-1605-SN Standard Control Station Combiner, 150-174 MHz, 16 Channel N (F) VHF 150 – 174 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1517-3205-SN Standard Control Station Combiner, 150-174 MHz, 32 Channel N (F) VHF 150 – 174 18dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS3845-0405-SN Standard Control Station Combiner, 380-450 MHz, 4 Channel N (F) UHF 380 – 450 8dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS3845-0805-SN Standard Control Station Combiner, 380-450 MHz, 8 Channel N (F) UHF 380 – 450 11.5dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS3845-1205-SN Standard Control Station Combiner, 380-450 MHz, 12 Channel N (F) UHF 380 – 450 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS3845-1605-SN Standard Control Station Combiner, 380-450 MHz, 16 Channel N (F) UHF 380 – 450 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS3845-3205-SN Standard Control Station Combiner, 380-450 MHz, 32 Channel N (F) UHF 380 – 450 17dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1517-1205-SN Standard Control Station Combiner, 150-174 MHz, 12 Channel N (F) VHF 150 – 174 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1315-3205-SN Standard Control Station Combiner, 132-150MHz, 32 Channel N (F) VHF 130 – 150 18dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1517-0405-SN Standard Control Station Combiner, 150-174MHz, 4 Channel N (F) VHF 150 – 174 8dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1517-0805-SN Standard Control Station Combiner, 150-174MHz, 8 Channel N (F) VHF 150 – 174 11dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1315-0405-SN Standard Control Station Combiner, 132-150 MHz, 4 Channel N (F) VHF 130 – 150 8dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1315-0805-SN Standard Control Station Combiner, 132-150 MHz, 8 Channel N (F) VHF 130 – 150 11dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1315-1205-SN Standard Control Station Combiner, 132-150 MHz, 12 Channel N (F) VHF 130 – 150 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)
CS1315-1605-SN Standard Control Station Combiner, 132-150 MHz, 16 Channel N (F) VHF 130 – 150 14dB (typ.) 0MHz > 14dB Per Channel: 50 (continuous)